Machine tool metrology.
Alignment, calibration and volumetric error compensation, for H&H machines and for machine tools built by other manufacturers. Engineers and equipment travel to the machine, including to sites in North America.
- ISO 230-2
- VDI/DGQ 3441
- ASME B5.54
Methods
Laser interferometry
Positioning accuracy and repeatability of each linear axis, measured in both directions at target positions along the travel.
Ballbar
Two axes interpolate a circle together. The trace shows squareness, reversal behaviour and servo mismatch between the axes.
Volumetric error compensation
Errors are mapped across the working volume and compensated in the control, then the machine is re-measured to confirm the result.
HeadCal
The probe in the A/C head measures a reference sphere at a set of head positions. The tool vector is calibrated from the results and written to the control, so the tool tip stays on point as A and C move.
Results are reported to ISO 230-2, VDI/DGQ 3441 or ASME B5.54, as your quality system requires. Documentation is prepared for AS9100 and Nadcap environments, where machine accuracy has to be shown on paper.
How a calibration runs
-
Level
The machine is levelled with electronic levels before anything is measured.
-
Align
Straightness and squareness of the axes are verified and adjusted with the alignment laser.
-
Calibrate
Positioning of each linear axis by laser interferometry to ISO 230-2, and ballbar circular tests. On five-axis heads, HeadCal calibrates the tool vector by probing a reference sphere.
-
Map and compensate
Errors are mapped through the working volume and the error map is compensated in the control.
-
Verify
The machine is re-measured after compensation to confirm the result, reported to the standard your quality system uses.
Equipment
- Laser interferometer
- 3-plane alignment laser
- Wireless electronic levels (0.001 mm/m)
- Renishaw wireless ballbar
- Electronic autocollimator
- Invar length bars
- Test mandrels
- Granite references
Tell us the machine, its control, where it is and the standard the report has to meet.